We recommand the following configuration tips when you try to configure the Smartmaster Pro with Powerdale Cluster and Advance Charger
Advance #
- TIP 1: advance use OCPP 1.5
- TIP 2: find the Karo number : Charge Box ID => NeXXtenderKaroXXXX
- TIP 3: find IP address : URL => https://IP address:9090/axis2/services/ChargePointService
- TIP4: Modify Nexxtgem parameters in the webapp
You can also download our Tips here
Cluster #
- TIP 1 : In the “wizard”, you can easily duplicate clusters
- TIP 2 : use the same “Communication unit” for all clusters connected to the same controller.
- TIP 3 : Don’t forget phase rotation in the primary phase (Cluster 1 => L1, Cluster 2 =>L2,..)
- TIP 4 : If they are 16 Clusters, Connector ID = 1 for Cluster 1 to Connector ID 16 for Cluster 16.
- TIP 5 : Cluster use OCPP 1.5.
- TIP 6 : find IP address for each controler : URL =>https://IPaddress:9090/axis2/services/ChargePointService
- TIP 7 : find the Controleur number:Charge Box ID=> NexxtenderCluster-XXXXX-XX-XXXX-XXXXX
You can also download our Tips here